Michael,
See the Advisory above re segregation of sterile & non sterile stock from the CEC. You have until DEC 2 to comply fully after risk assessment & review .
Good luck
Sally
[cid:image002.jpg@01D7AFC3.D2D72E80]Sally Holmes
Quality Manager and Infection Control & Prevention Coordinator
Lakeview Private Hospital|17-19 Solent Circuit Norwest NSW 2153
http://www.lakeviewprivate.com.au
Can you tells us a bit more?
What area was the storage room/area in?
What was the sterile and non-sterile stock?
Regards
Glenys
Glenys Harrington
Consultant
Infection Control Consultancy (ICC)
P.O. Box 6385
Melbourne
Australia, 3004
M: +61 404816434
E: infexion@ozemail.com.au
[Description: ICC Diagram ICCversion]
I’ve just had my mind blown by an auditor who tells me I cannot store any ‘sterile stock’ on a shelf with non-sterile stock. I reply by saying that no sterile RMDs are stored on shelves with non-sterile stock, and they say, no ANYTHING that comes sterile should not be on the same shelf with something non-sterile.
Have I missed something? I have always understand that the very specific storage requirements for RMDs did not apply to most commercially sterilised single use items. Sure, there are commercially sterilised disposables that have very specific storage requirements, but the majority of high volume disposable sterile goods can be safely stored on a shelf with non-sterile stock in an appropriately air-conditioned storage room. AS4187 does not cover storage of non-RMDs, correct?
Can someone either tell me I am wrong, and I missed this big time, or that I did not miss anything, and the auditor is incorrect. Or some variation of these.
Help?
Thanks
Michael
Michael Wishart | Infection Control Coordinator, CICP-E
St Vincent’s Private Hospital Northside | 627 Rode Road CHERMSIDE QLD 4032
M +61 448 954 282 | T +61 7 3326 3068 | F +61 7 3607 2226
E michael.wishart@svha.org.au |
W https://www.svphn.org.au
St Vincent’s Private Hospital Brisbane | 411 Main Street KANGAROO POINT QLD 4169
M +61 448 954 282 | T +61 7 3240 1208 | F +61 7 3240 1166
E michael.wishart@svha.org.au |
W https://www.svphb.org.au
[http://i8.cmail19.com/ei/t/6C/F77/A00/141133/csfinal/StaticEmailFooter-SVPHN-Celebrating20Years-650×150-9900000000079e3c.png]
[cid:image001.png@01D7AFB0.F3A523F0]
This email and any attachments to it (the “Email”) is confidential and is for the use only of the intended recipient, and may not be duplicated or used by any other party without the express consent of the sender. If you are not the intended recipient of the Email, please notify the sender immediately by return email, delete the Email, and do not copy, print, retransmit, store or act in reliance on the Email. St Vincent’s Health Australia (“SVHA”) does not guarantee that the Email is free from errors, viruses or interference. Emails to and from SVHA or its related entities may be scanned and filtered in locations outside Australia
MESSAGES POSTED TO THIS LIST ARE SOLELY THE OPINION OF THE AUTHOR, AND DO NOT REPRESENT THE OPINION OF ACIPC.
The use of trade/product/commercial brand names through the list is discouraged by ACIPC. If you wish to discuss specific reference to products or services by brand or commercial names, please do this outside the list.
Archive of all messages are available at http://aicalist.org.au/archives – registration and login required.
Replies to this message will be directed back to the list. To create a new message send an email to acipclist@acipc.org.au
To send a message to the list administrator send an email to admin@acipc.org.au
You can unsubscribe manually from this list by sending ‘signoff acipclist’ (without the quotes) to listserv@aicalist.org.au
MESSAGES POSTED TO THIS LIST ARE SOLELY THE OPINION OF THE AUTHOR, AND DO NOT REPRESENT THE OPINION OF ACIPC.
The use of trade/product/commercial brand names through the list is discouraged by ACIPC. If you wish to discuss specific reference to products or services by brand or commercial names, please do this outside the list.
Archive of all messages are available at http://aicalist.org.au/archives – registration and login required.
Replies to this message will be directed back to the list. To create a new message send an email to acipclist@acipc.org.au
To send a message to the list administrator send an email to admin@acipc.org.au
You can unsubscribe manually from this list by sending ‘signoff acipclist’ (without the quotes) to listserv@aicalist.org.au
______________________________________________________________________
While this email message has been scanned for the presence of computer viruses,
and Lakeview Private Hospital has taken every reasonable precaution to
minimise the risk from them, we cannot accept liability from same. You should carry
out your own virus checks before opening attachments.
This email and any attachments are confidential and may be privileged or contain
confidential information and is intended only for use of the addressee. Any
unauthorised direct or indirect dissemination, use, disclosure or copying is strictly
prohibited and may be unlawful. Please delete any emails received in error.
Any views, advice or opinions contained in this communication are those of the
individual sender except where the sender specifies and with authority states them
to be the views of Lakeview Private Hospital.
______________________________________________________________________
MESSAGES POSTED TO THIS LIST ARE SOLELY THE OPINION OF THE AUTHOR, AND DO NOT REPRESENT THE OPINION OF ACIPC.
The use of trade/product/commercial brand names through the list is discouraged by ACIPC. If you wish to discuss specific reference to products or services by brand or commercial names, please do this outside the list.
Archive of all messages are available at http://aicalist.org.au/archives – registration and login required.
Replies to this message will be directed back to the list. To create a new message send an email to acipclist@acipc.org.au
To send a message to the list administrator send an email to admin@acipc.org.au
You can unsubscribe manually from this list by sending ‘signoff acipclist’ (without the quotes) to listserv@aicalist.org.au